← Sample reports

Fictional sample

Sample home inspection

Sample Home Inspections · Saturday, September 12, 2026

124 Maple Street, Sampletown

Inspected by Alex Rivera

This page is a public sample of a IntellectSpect client report. Names, the address, and the findings are fictional. It is not a live job and it is not a client portal link.

Inspectors attach radon, sewer, and termite PDFs on Conditions. Those files list here, separate from what we observed on the house.

Property facts

Inspection type
Home inspection
Age
28 years
Size
2,140 sq ft
Foundation
Poured concrete
Occupancy
Occupied
Utilities
On

Third-party reports

Attached PDFs from this job. Not part of our findings.

  • Radon: Radon test report

    Lab PDF attached on this job. Not one of our findings.

    Sample PDF (fictional, not a live lab file)

  • Sewer: Sewer camera report

    Camera operator PDF attached on this job. Not one of our findings.

    Sample PDF (fictional, not a live lab file)

Summary of Defects

  1. Finding 1 of 2 · Repair

    Roofing · Flashing

    What we observed

    Step flashing at the chimney is short and open at the counterflashing.

    Implication

    Water can enter the roof deck at the chimney chase during wind-driven rain.

    Recommendation

    Have a licensed roofer rework the step and counterflashing.

  2. Finding 2 of 2 · Safety

    Electrical · Receptacles

    What we observed

    The kitchen counter receptacle left of the sink did not trip on GFCI test.

    Implication

    A ground-fault at that outlet may not shut off as required.

    Recommendation

    Have a licensed electrician repair or replace the GFCI protection.